![]() |
||
| An ISO 9001 Certified Company |
Redefining Automations.... |
|
Temperature Controllers |
Featured Products: |
|
Temperature Controller Without DataLogger Model: TC-R200 Temperature Controller With Data Logger Model : VG-TC __________________________________________________________________________________ Temperature Controller Without Datalogger Model: TC-R200 :- Temperature Controller TC-R200 Features :-
It is 3 digit-7 Segment with calibration Temperature-Controller Instrument, used to measure and control temperature for 0 to 200 centigrade from a sensor RTD, has a built-in level controller (Can be used as door switch), and a control-Relay, which can be cut-off if level input is not sensed. It has an additional relay, Type-Relay, which can be used with different function. Set-point. A relay indication is provided in front for relay status and three membrane-push-buttons, Up-Arrow, Left-Arrow, Enter-Arrow are provided to view and edit parameters. There are two modes for operation. Note: If two wire RTD is used then short pin 5 & 6 and re-calibrate to compensate wire length of RTD (If large length).
Measure-Mode At power on and if none of switch is pressed display start showing Measured Temperature value in centigrade if calibrated correctly and relays start functioning as per parameter settings. Press Sw3 (Enter-Arrow) to see Set-Point, Or press both Sw1 (Up-Arrow) and Sw2 (Left-Arrow) to Program Parameters. Program-Mode There are 14 parameters can be viewed/edited one by one in this mode. Parameters are abbreviated on display and are shown as follows. (3) Band as bA (13) Calibrate-Low as CL To exit any time from Program mode press both Sw1 (UpArrow) and Sw2 (LeftArrow) again. Note: If this mode is left for sometime without any action for preset internal time, Measure-Mode will be established automatically. For Further Help please download Help File for TC-R200 _________________________________________________________________________________ Temperature Controller With Data Logger Model : VG-TC Temperature Controller VG-TC Features :- 240V 10% A.C Input Supply
12V 10% A.C Supply for Level Sensors Instrument Front View:-
Low: - Low Relay Output on Indication Cont: - Control Relay Output On Indication High: - High Relay Output on Indication Following push button is given for settings. Program/ClrMode Instrument Back View:-
1) Input +ve of Pt100 Amplifier 2) Output +15V for Pt100 Amplifier 3) Output Ground(+15V) for Pt100 Amplifier 4) A7 Connection of RS485, connected to A7 of RS485-To- RS232-Converter card. This is also connected to all A7 connection of all other Instruments. 5) B6 Connection of RS485, connected to B6 of RS485-To- RS232-Converter card. This is also connected to all B6 connection of all other Instruments. 6) Common Connection of RS485, connected to Common of RS485-To- RS232-Converter card. This is also connected to all Common connection of all other Instruments. 7) En (Enable) Connection of RS485, connected to En of RS485-To- RS232-Converter card. This is also connected to all En connection of all other Instruments. 8) LL (Low Level) connected to Low Level Probe. 9) Optional For OverFlow. 10) Not Used 11) 12V AC Supply for Level Controller (Built-In).Also used as common point for Low Level & OverFlow sensor. 12) 12V AC Supply for Level Controller (Built-In). 13) 230 V AC Supply. 14) Supply Earth. 15) 230 V AC Supply. 16) Common point For All Relays. 17) Not Used.(Optional For Dozing) 18) Not Used. 19) Not Used. 20) Not Used. 21) Normally open contact of Error relay. 22) Normally open contact of High temperature relay. 23) Normally open contact of Control temperature relay. 24) Normally open contact of Low temperature relay.
Error:-
Note: For Further Help please download Help File for VG-TC
|
|
Website best viewed under 1024 x 768 resolution.Website Designed and Manintained by VG Soni-Tech @Copyrights VG Soni-Tech 2008. |